Combustion analyzer: Ametek Thermox WDG-V

Prevention is so Easy… Living Through a Disaster Isn’t Ametek Thermox WDG-V Combustion Analyzer Sensor PDF Why the need for a combustion analyzer? The reliable identification of low combustion oxygen in a fired heater or boiler has always been critical to the effectiveness of the Burner Management System for proper control and safety. Low emission[…]

ABB EasyLine Series

EasyLine is both a powerful and affordable line of instruments for the monitoring of gas concentrations in numerous applications. The advantages to you – EasyLine offers: New: Flame Ionization Detector Proven analyzer technology Intuitive operation via five buttons New: UV photometer Infrared photometer Paramagnetic oxygen analyzer Electrochemical oxygen sensor Thermal conductivity analyzer Trace oxygen analyzer[…]

Ametek CG1000

The CG1100 is a smart sensor capable of detecting oxygen in your sample from 0.1 ppm to 100%. This analyzer is designed specifically for use in applications where fast response over a wide range of oxygen is required. The sample can be pulled through the analyzer using an aspirator (optional) thereby eliminating the need for[…]

Ametek CG1000-RTP

The importance of oxygen contamination control is best illustrated in the deposition of the titanium silicide used to assure adequate conductivity between the silicon material and the overlaying metal conductor. When oxygen is present during the deposition, it reacts with the titanium and contaminates the process. The Dycor CG 1 000 RTP Oxygen Analyzer improves[…]

Ametek CG1100

The CG1100 is a smart sensor capable of detecting oxygen in your sample from 0.1 ppm to 100%. This analyzer is designed specifically for use in applications where fast response over a wide range of oxygen is required. The sample can be pulled through the analyzer using an aspirator (optional) thereby eliminating the need for[…]

Ametek Model CG1100 Oxygen O2 Analyzer

Ametek Model CG1100 Oxygen O2 Analyzer Overview The Ametek Model CG1100 Oxygen O2 Analyzer is easy to Integrate into your host controller and data acquisition system: The CG1100 is equipped with an RS-232 and two RS-485 ports: It comes with configurator software for initial setup of operating parameters and accepts user-provided software for efficient integration[…]

Ametek CG1100GS

The CG1100-GS is a smart sensor designed specifically for use in air separation and other applications where fast response over a wide range of oxygen is required. It uses a zirconium oxide sensor that provides quick response, is non-depleting, and will not fail to zero reading, thereby protecting your process. APPLICATIONS Air Separation Blanket /Purge[…]

Ametek HUMOX

Thermox introduces the first analyzer that measures both percent moisture and percent oxygen in flue gases. This 2-in-1 analyzer is designed for flue gas applications up to 3200°F (1760°C) containing up to 85% moisture! It is ideal for direct-fired applications where accurate measurement of moisture and oxygen is critical for process control or emissions-related monitoring.[…]

Ametek PreMix 2000

The Thermox PreMix 2000 analyzer accurately and continuously measures the proportions of oxygen and fuel in pre-mix gases, operating in either excess fuel or excess air conditions. The analyzer is fed a small sample of the air/fuel mixture, burns it and then measures the results. APPLICATIONS Glass forehearth Air/fuel mixtures Glass fiber apparatus Open flame[…]

Ametek TM2000

The TM2000 oxygen analyzer protects industrial processes by quickly responding to changes using an industryproven zirconium oxide sensor. It operates within a wide operating range of 0.1 ppm to 100% oxygen, and can accurately respond from atmosphere to low ppm oxygen levels in just seconds. In addition, the TM2000 can detect excess combustibles process upsets[…]

Ametek WDG INSITU

Principle of Operation: Direct sensing insitu probe using a zirconium oxide electrochemical cell for oxygen measurement. Completely field serviceable. Display Range: Oxygen: 0.1-100% Output Range: Oxygen: From 0-1% to 0-100% Accuracy: ±1% of measured value or ±0.05% oxygen, whichever is greater Response: < 3 secs. to calibration gas. 63% of a process step change <[…]

Ametek WDGHPII

Principle of Operation: Convective oxygen analyzer using a zirconium oxide electrochemical cell for oxygen measurement. Completely field serviceable. Display Range: Oxygen: 0.1-100% Output Range: Oxygen: From 0-1% to 0-100% Accuracy: ±0.75% of measured value or ±0.05% oxygen, whichever is greater Response: < 3 sec. to calibration gas. 63% of process step change <16 secs. with[…]

Ametek WDG-IV

Principle of Operation: Close-coupled extractive oxygen analyzer using a zirconium oxide electrochemical cell for oxygen measurement. Completely field serviceable. Display Range: Oxygen: 0.1-100% Output Range: Oxygen: From 0-1% to 0-100% Accuracy: ± 0.75% of measured value or ± 0.05% oxygen, whichever is greater Response: Oxygen: 63% of a process step change < 3 secs. Drift:[…]

Ametek WDGIVC

Principle of Operation:                                               Close-coupled extractive oxygen, combustibles and methane analyzer using zirconium oxide for oxygen measurement and catalytic detectors for both combustibles and methane. Completely field serviceable. Display Range: Oxygen: 0.1-100% Combustibles: 0-10,000 ppm Methane: 0-5% Output Range: Oxygen: From 0-1 to 0-100% Combustibles: From 0-2,000 ppm to 0-10,000 ppm Methane: 0-5% Accuracy: Oxygen: ±0.75%[…]

Ametek WDGIVCM

Principle of Operation: Close-coupled extractive oxygen, combustibles and methane analyzer using zirconium oxide for oxygen measurement and catalytic detectors for both combustibles and methane. Completely field serviceable. Display Range: Oxygen: 0.1-100% Combustibles: 0-10,000 ppm Methane: 0-5% Output Range: Oxygen: From 0-1 to 0-100% Combustibles: From 0-2,000 ppm to 0-10,000 ppm Methane: 0-5% Accuracy: Oxygen: ±0.75%[…]

Ametek WDGIVEEX

Principle of Operation: Close-coupled extractive oxygen and combustibles analyzer using zirconium oxide for oxygen measurement and a catalytic detector for combustibles. Completely field serviceable. Display Range: Oxygen: 0.1-100% Combustibles: 0-10,000 ppm or 0-5% Output Range: Oxygen: From 0-1% to 0-100% Combustibles: From 0-2,000 ppm to 0-10,000 ppm from 0-1% to 0-5% Accuracy: Oxygen: ±0.75% of[…]

Buhler BA3 Select

The BA 3 select is a gas analyzer for 19″ rack- mounting. Its modular design provides configuration from simple oxygen- up to multi-component devices. This enables the simultaneous measurement of up to four gas components. Due to its outstandig advantage of the modular design concopt, measuring cells can easily be added on-site. This allows the[…]

Buhler BA1000

The Buhler Model BA 1000 solid-state oxygen analyzer had been developed for in-situ applications. The cell is self-controlling and therefore well- suited for applocations in flue fas of similar matrices. The dynamic sensor measures oxygen without using a reference gas. APPLICATION Furnaces Industrial heating facilities Industrial combustion facilities Farming in silos Medical Biotechnology BENEFITS Low[…]

Buhler BA2000

In combustion applications such as process heaters, steam generation boilers or fumaces, the amount of air needed to reach optimum system efficiency can vary rapidly. The optimum heat rate for these units, which may lie within narrow limits, can be achieved with the BA2000. BENEFITS Fast response Easy replacement of probe and filter Easy to[…]

Buhler BA3500

The central processing unit of BA 3500 communicates with up to three measuring modules, equippedwith diverse measuring cells. Differen measurement combinations are possible. One channel mag be equipped with paramagnetic cell measuring %-range Oxygen, while the second channel measures oom-Oxygen using a Zirconia cell. Another combination may consist of IR-measuring cell, either on each measuring[…]

Buhler BA4000

The portable Buhler O2  Analyzer is suitable for various applications in non-hazardous areas. As an option the BA 4000 can be equipped with an integrated sample gas pump. The optional sampling pump is required for applications at atmospherica pressure or light vacuum and is switched on and off by an intergrated switch in front of[…]

Buhler BA4000 Injection

The portable Buhler O2 -analyzer BA 4000 Inj. is designed for oxygen analysis in small packages. Typically, it is used for analysis of head space volume in bottles, cans of sort packages. Two different models handle different package sizes.          BA 4000 Inj. GV – Volumes >35ml                          Integrated sample pump controlled[…]

Buhler BA4510

The BA4510 is designed for measurements of oxygen traces in inert gases. Its is based on an advanced, zirconia measurement cell. The highly selective cell combines high mechanical strength with consistent accuracy. With inert gases, the cell delivers an increasing signal if the partial pressure of oxygen drops thus giving a highly precise measurement of[…]

Buhler BA5000

The BA 5000 gas analyzer can measure up to 4 gas components. The instrument can be configured a maximum of three infrared gases usch as CO, CO2 , NO, SO2 or CH4 plus the measure of O2 with an electrochemical fuel cell. For oxygen analysis, the BA5000 can be equipped with either electrochemical of paramagnetic[…]

Buhler BA6000IR

The BA 6000 IR single or dual channel gas analyzer operates as a NDIR instrument. It is ideally suited to measure any gas in the IR region betwee 2 and 9 µm, such as CO, CO2, NO, SO2, NH3, H2O, CH4 and other hydrocarbons. Single channel analyzers measure one gas component while dual channel analyzers[…]

Buhler BA6000o2

The BA 6000 oxygen analyzer is based on the para-pneumatic principle which is derived from paramagneti technology. Unlike traditional paramagnetic (dumb-bell) analyzers, this instrument has no moving parts in the measurement cell and is impervious to the effects of vibration. This analyzer is ideally suited for reactive gas mixtures of where corrosion of a traditional[…]

Buhler BA8000

When sampling reactive or highly corrosive gases, the insitu measurement technique is the preferred approach. It solves many sampling and analytical problems inherent is difficult applications. The BA 8000 In-situ Gas Analyzer, is designed to meet the most difficult gas measurement challenges. Based on the state-of-the art tunable diode laser technology, the Model BA 8000[…]

Buhler Bunox

The BUNOx gas converter allows easy and cost effective detection of nitrogen oxides (NOx) components in the flue gas (NO and NO2). BunOx converts almost 100% of the NO2 content of a sample gas to NO by means of a replaceable reactor cartridge. The resulting NO gas in measurable by any commercially available IR-analyzer. The[…]