Bühler ATEX pumps are the most durable

According to the ATEX regulations a regular inspection of pumps is necessary. Bühler pumps have a very long lifetime, the inspection interval is 43,800 hours or 5 years! The inspection extends to all moving parts of the pumps including the motor. Because the removal and return of the pump is associated with business interruption and[…]

Buhler AGFFE

Filter types AGF-FE have been particulary designed to fit into front panels of analyzers or systems. The main body is fixed to the front panel. The filter bowl fits on a thread on the main body and seals on a O-Ring. Change of filter elements is done by turning off the bowl. The dirt load[…]

Buhler AGFFE4

Buhler’s AGF-FE-4 filters are designed for panel mounting. The main body is attached to the front panel. The filter bowl threads onto the main body and seals with an O-Ring. Changing filter media is done by simply removing the bowl. The dust loading on the filter is visible through the transparent bowl. The sample gas[…]

Buhler AGFPV30

Sample gas streams must be conditioned to provide particulate and moisture-free gas to the analyze. The AGF-PV-30 with the Buhler Unique QC bracket provides fine filtration and easy replacement of the filter media can be changed in an matter of seconds. The QC bracket rotates 180° making the mounting of the bracket of the filter[…]

Buhler AGFT30

Sample gas streams must be conditioned to provide particulate and moisture-free gas to the analyzer. Some applications require components made of highly corrosion resistant materials while others require inert materials. The AGF-T-30 is made of Duran glass and PTFE and is an excellent solution for many corrosive applications and most reactive gas applications. The filter[…]

Buhler AGFVA23

Sample gas streams must be conditioned to provide particulate and moisture-free gas to the analyzer. The AGF-VA-23 with the Buhler Unique QC mounting block provides fine filtration and easy replacement of the filter media without the use of tools. This means the filter media can be changed in a matter of seconds. The QC block[…]

Buhler AGFVA350

Sample gas streams must be conditioned to provide particulate and moisture-free gas to the analyzer. The AGF-VA-350  provides fine filtration and easy replacement of the filter media without the use of tools. This means the filter media can be changed in a matter of seconds. The mounting bracket can be installed at an angle of[…]

Buhler AHF22

The traditional design of heated particulate filters requires considerable maintenance and down time due to the work required to change the filter media. Buhler’s AHF-22 incorporates a new advanced design that eliminates much of this work and sets new standards for ease and speed of maintenance. A spent filter can be changed in seconds and[…]

Buhler BF2S

Using the croos flow (inertial) principle, this filter is an alternative to traditional filters. Filtre of the type provide the lowest maintenance cost and longest life of any filter technology. A grooved core is pressed into a filter element made of sintered stainless steel. The main sample gas stream enters the groove from the top[…]

Buhler EGK2EX

Accurate measurements of gasas require gas samples with stable dew points even under harsh ambient conditions. The EGK models provide a CFC-free, compressor-type cooling system connected to a cooling block. The cooling block evenly dissipates the heat thuis supporting the highly efficient heat exchangers. The temperature of the cooling block is regulated by the Buhler[…]

Buhler EGK4

Accurate measurements of gases require gas samples with stable dew points even under harsh ambient conditions. The EGK models provide a compressor-type cooling system connected to a cooling block. The cooling block evenly dissipates the heat thus supporting the highly efficient heat exchangers. The temperature of the cooling block is regulated by the Buhler Constant[…]

Buhler EGK12

Accurate measurements of gases require gas samples with stable dew points even under harsh ambient conditions. The EGK models provide a compressor-type cooling system connected to a cooling block. The cooling block evenly dissipates the heat thus supporting the highly efficient heat exchangers. The temperature of the cooling block is regulated by the Buhler Constant[…]

Buhler EGK219

ccurate measurements of gases require gas samples with stable dew points even under harsh ambient conditions. The EGK models provide a compressor-type cooling system connected to a cooling block. The cooling block evenly dissipates the heat thus supporting the highly efficient heat exchangers. The temperature of the cooling block is regulated by the Buhler Constant[…]

Buhler KAGFPV30

The removal of aerosols from sample gas streams is a requirement in many applications. To meet this need, the Buhler Model K-AGF-PV-30-A filter makes use of a coalescing element made of borosilicate fibers. The gas stream passes through the element from inside to outside. The aerosols are caught in the matrix forming steadily growing droplets[…]

Buhler KAGFVA23

The removal of aerosols from sample gas streams is a requirement in many applications. To meet this need, the Buhler Model K-AGF-VA-23 filter makes use of a coalescing element made of borosilicate fibers. The gas stream passes through the element from inside to outside. The aerosols are caught in the matrix forming steadily growing droplets[…]

Buhler P2

Buhler P2 The transportation of sample gas in sample conditioning systems requires reliable sample pumps. The corrosive nature of the gas and the potential of condensate formation are the real challenges for any pump. These sample pump are equipped with a bellows made from solid PTFE. This design has demonstrated the highest reliability and long[…]

Buhler P4

The transportation of sample gas in sample conditioning systems requires reliable sample pumps. The corrosive nature of the gas and the potential of condensate formation are the real challenges for any pump. These sample pump are equipped with a bellows made from solid PTFE. This design has demonstrated the highest reliability and long lifetime in[…]

Buhler PKE5

The PKE models feature a semiconductor Peltier cooling system with an aluminum cooling block. Fitted into the block are one or two removable high efficient heat exchanger made of stainless steel, DURAN-glass or PVDF. The PKE 5 is designed for moderate ambient and gas temperatures (150 l/h @ 70°C) and an inlet dew point of[…]

Buhler RAFPV30

The analysis of ambient air requires the conditioning of the sample gas stream to eliminate the fugitive  particulate matter. The Buhler RAV-PV-30 filter is equipped with a fine upstream filter element to accomplish this. BENEFITS Buhler Unique QC bracket Easy change of filter media without tools Versatile mounting bracket Buhler RAFPV30 PDF

Buhler SM6

These highly corrosion resistant flow meters are suitable for both liquid and gaseous applications. The SM-6-V combines a flow meter with a precision needle valve to regulate and adjust the flow. In applications where flow monitoring is critical, the flow meter can be equipped with a bi-stable flow sensor. Any deviation fron the set point[…]

Buhler SSM

Handling hazardous liquids or gases requires the use of flow meters with the vulnerable parts such as the metering glass protected against breakage. The S-SM safety flow meter provides sealed protection glass around the metering glass and an outer stainless steel shell with a sight window. A variety of construction materials is available to meet[…]