Bühler Technologies

Bühler ATEX pumps are the most durable

According to the ATEX regulations a regular inspection of pumps is necessary. Bühler pumps have a very long lifetime, the inspection interval is 43,800 hours or 5 years! The inspection extends to all moving parts of the pumps including the motor. Because the removal and return of the pump is associated with business interruption and[…]

Buhler 222

In gas analysis, the sample point is a critical interface between the process and the analysis system. Probes for this harsh and demanding environment must be specially designed. Robust and flexible design provides low operational cost. The GAS 222 series of probes features a modular design allowing the easy adaptation to application specific requirements. The[…]

Buhler ADFPV30l

In some analyzer systems designs, removal of gas components by adsorbent or absorbent techniques may be required. For this purpose, Buhler offers a modified filter which can be filled with the appropriate sorbent material. The gas enters at the bottom of the unit and exits at the top, maximizing contact time with the sorbent material.[…]

Buhler AGFFA5

Buhler’s AGF-FA-5 filters are designed for panel mounting. The main body is attached onto the front panel. The filter bowl threads onto the main body and seals with an O-Ring. All wetted parts resist to aggressive media. The filter element consists of sintered PTFE. Changing filter media is done by simply removing the bowl. The[…]

Buhler AGFFE

Filter types AGF-FE have been particulary designed to fit into front panels of analyzers or systems. The main body is fixed to the front panel. The filter bowl fits on a thread on the main body and seals on a O-Ring. Change of filter elements is done by turning off the bowl. The dirt load[…]

Buhler AGFFE4

Buhler’s AGF-FE-4 filters are designed for panel mounting. The main body is attached to the front panel. The filter bowl threads onto the main body and seals with an O-Ring. Changing filter media is done by simply removing the bowl. The dust loading on the filter is visible through the transparent bowl. The sample gas[…]

Buhler AGFPV30

Sample gas streams must be conditioned to provide particulate and moisture-free gas to the analyze. The AGF-PV-30 with the Buhler Unique QC bracket provides fine filtration and easy replacement of the filter media can be changed in an matter of seconds. The QC bracket rotates 180° making the mounting of the bracket of the filter[…]

Buhler AGFT30

Sample gas streams must be conditioned to provide particulate and moisture-free gas to the analyzer. Some applications require components made of highly corrosion resistant materials while others require inert materials. The AGF-T-30 is made of Duran glass and PTFE and is an excellent solution for many corrosive applications and most reactive gas applications. The filter[…]

Buhler AGFVA23

Sample gas streams must be conditioned to provide particulate and moisture-free gas to the analyzer. The AGF-VA-23 with the Buhler Unique QC mounting block provides fine filtration and easy replacement of the filter media without the use of tools. This means the filter media can be changed in a matter of seconds. The QC block[…]

Buhler AGFVA350

Sample gas streams must be conditioned to provide particulate and moisture-free gas to the analyzer. The AGF-VA-350  provides fine filtration and easy replacement of the filter media without the use of tools. This means the filter media can be changed in a matter of seconds. The mounting bracket can be installed at an angle of[…]

Buhler AHF22

The traditional design of heated particulate filters requires considerable maintenance and down time due to the work required to change the filter media. Buhler’s AHF-22 incorporates a new advanced design that eliminates much of this work and sets new standards for ease and speed of maintenance. A spent filter can be changed in seconds and[…]

Buhler BA3 Select

The BA 3 select is a gas analyzer for 19″ rack- mounting. Its modular design provides configuration from simple oxygen- up to multi-component devices. This enables the simultaneous measurement of up to four gas components. Due to its outstandig advantage of the modular design concopt, measuring cells can easily be added on-site. This allows the[…]

Buhler BA1000

The Buhler Model BA 1000 solid-state oxygen analyzer had been developed for in-situ applications. The cell is self-controlling and therefore well- suited for applocations in flue fas of similar matrices. The dynamic sensor measures oxygen without using a reference gas. APPLICATION Furnaces Industrial heating facilities Industrial combustion facilities Farming in silos Medical Biotechnology BENEFITS Low[…]

Buhler BA2000

In combustion applications such as process heaters, steam generation boilers or fumaces, the amount of air needed to reach optimum system efficiency can vary rapidly. The optimum heat rate for these units, which may lie within narrow limits, can be achieved with the BA2000. BENEFITS Fast response Easy replacement of probe and filter Easy to[…]

Buhler BA3500

The central processing unit of BA 3500 communicates with up to three measuring modules, equippedwith diverse measuring cells. Differen measurement combinations are possible. One channel mag be equipped with paramagnetic cell measuring %-range Oxygen, while the second channel measures oom-Oxygen using a Zirconia cell. Another combination may consist of IR-measuring cell, either on each measuring[…]

Buhler BA4000

The portable Buhler O2  Analyzer is suitable for various applications in non-hazardous areas. As an option the BA 4000 can be equipped with an integrated sample gas pump. The optional sampling pump is required for applications at atmospherica pressure or light vacuum and is switched on and off by an intergrated switch in front of[…]

Buhler BA4000 Injection

The portable Buhler O2 -analyzer BA 4000 Inj. is designed for oxygen analysis in small packages. Typically, it is used for analysis of head space volume in bottles, cans of sort packages. Two different models handle different package sizes.          BA 4000 Inj. GV – Volumes >35ml                          Integrated sample pump controlled[…]

Buhler BA4510

The BA4510 is designed for measurements of oxygen traces in inert gases. Its is based on an advanced, zirconia measurement cell. The highly selective cell combines high mechanical strength with consistent accuracy. With inert gases, the cell delivers an increasing signal if the partial pressure of oxygen drops thus giving a highly precise measurement of[…]

Buhler BA5000

The BA 5000 gas analyzer can measure up to 4 gas components. The instrument can be configured a maximum of three infrared gases usch as CO, CO2 , NO, SO2 or CH4 plus the measure of O2 with an electrochemical fuel cell. For oxygen analysis, the BA5000 can be equipped with either electrochemical of paramagnetic[…]

Buhler BA6000IR

The BA 6000 IR single or dual channel gas analyzer operates as a NDIR instrument. It is ideally suited to measure any gas in the IR region betwee 2 and 9 µm, such as CO, CO2, NO, SO2, NH3, H2O, CH4 and other hydrocarbons. Single channel analyzers measure one gas component while dual channel analyzers[…]

Buhler BA6000o2

The BA 6000 oxygen analyzer is based on the para-pneumatic principle which is derived from paramagneti technology. Unlike traditional paramagnetic (dumb-bell) analyzers, this instrument has no moving parts in the measurement cell and is impervious to the effects of vibration. This analyzer is ideally suited for reactive gas mixtures of where corrosion of a traditional[…]

Buhler BA8000

When sampling reactive or highly corrosive gases, the insitu measurement technique is the preferred approach. It solves many sampling and analytical problems inherent is difficult applications. The BA 8000 In-situ Gas Analyzer, is designed to meet the most difficult gas measurement challenges. Based on the state-of-the art tunable diode laser technology, the Model BA 8000[…]

Buhler BF2S

Using the croos flow (inertial) principle, this filter is an alternative to traditional filters. Filtre of the type provide the lowest maintenance cost and longest life of any filter technology. A grooved core is pressed into a filter element made of sintered stainless steel. The main sample gas stream enters the groove from the top[…]

Buhler Bunox

The BUNOx gas converter allows easy and cost effective detection of nitrogen oxides (NOx) components in the flue gas (NO and NO2). BunOx converts almost 100% of the NO2 content of a sample gas to NO by means of a replaceable reactor cartridge. The resulting NO gas in measurable by any commercially available IR-analyzer. The[…]

Buhler EGK2EX

Accurate measurements of gasas require gas samples with stable dew points even under harsh ambient conditions. The EGK models provide a CFC-free, compressor-type cooling system connected to a cooling block. The cooling block evenly dissipates the heat thuis supporting the highly efficient heat exchangers. The temperature of the cooling block is regulated by the Buhler[…]

Buhler EGK4

Accurate measurements of gases require gas samples with stable dew points even under harsh ambient conditions. The EGK models provide a compressor-type cooling system connected to a cooling block. The cooling block evenly dissipates the heat thus supporting the highly efficient heat exchangers. The temperature of the cooling block is regulated by the Buhler Constant[…]

Buhler EGK12

Accurate measurements of gases require gas samples with stable dew points even under harsh ambient conditions. The EGK models provide a compressor-type cooling system connected to a cooling block. The cooling block evenly dissipates the heat thus supporting the highly efficient heat exchangers. The temperature of the cooling block is regulated by the Buhler Constant[…]

Buhler EGK219

ccurate measurements of gases require gas samples with stable dew points even under harsh ambient conditions. The EGK models provide a compressor-type cooling system connected to a cooling block. The cooling block evenly dissipates the heat thus supporting the highly efficient heat exchangers. The temperature of the cooling block is regulated by the Buhler Constant[…]

Buhler KAGFPV30

The removal of aerosols from sample gas streams is a requirement in many applications. To meet this need, the Buhler Model K-AGF-PV-30-A filter makes use of a coalescing element made of borosilicate fibers. The gas stream passes through the element from inside to outside. The aerosols are caught in the matrix forming steadily growing droplets[…]

Buhler KAGFVA23

The removal of aerosols from sample gas streams is a requirement in many applications. To meet this need, the Buhler Model K-AGF-VA-23 filter makes use of a coalescing element made of borosilicate fibers. The gas stream passes through the element from inside to outside. The aerosols are caught in the matrix forming steadily growing droplets[…]

Buhler MAS

The Buhler MAS system combines a 19″gas analyzer and a sample conditioning system in a rigid transport case. The conditioning components, including the cooler, filter, pump and flow meter, are customized to the application. The transport case is a double wall construction and highly shock resistant. Wheels, carrying handles and a handle for pulling the[…]

Buhler P2

Buhler P2 The transportation of sample gas in sample conditioning systems requires reliable sample pumps. The corrosive nature of the gas and the potential of condensate formation are the real challenges for any pump. These sample pump are equipped with a bellows made from solid PTFE. This design has demonstrated the highest reliability and long[…]

Buhler P4

The transportation of sample gas in sample conditioning systems requires reliable sample pumps. The corrosive nature of the gas and the potential of condensate formation are the real challenges for any pump. These sample pump are equipped with a bellows made from solid PTFE. This design has demonstrated the highest reliability and long lifetime in[…]

Buhler PKE5

The PKE models feature a semiconductor Peltier cooling system with an aluminum cooling block. Fitted into the block are one or two removable high efficient heat exchanger made of stainless steel, DURAN-glass or PVDF. The PKE 5 is designed for moderate ambient and gas temperatures (150 l/h @ 70°C) and an inlet dew point of[…]

Buhler RAFPV30

The analysis of ambient air requires the conditioning of the sample gas stream to eliminate the fugitive  particulate matter. The Buhler RAV-PV-30 filter is equipped with a fine upstream filter element to accomplish this. BENEFITS Buhler Unique QC bracket Easy change of filter media without tools Versatile mounting bracket Buhler RAFPV30 PDF

Buhler SCS19

The Buhler Model SCS Sample Gas Conditioner is a pre-engineered, pre-packaged sampling system including all pneumatic components that are normally used in gas analysis systems. The SCS integrates the following pneumatic functions: sample pump, sample cooler, calibration gas valves, flow meters, condensate drains, particulate filtration, and operator interface, PLC or data logger control features all[…]

Buhler SM6

These highly corrosion resistant flow meters are suitable for both liquid and gaseous applications. The SM-6-V combines a flow meter with a precision needle valve to regulate and adjust the flow. In applications where flow monitoring is critical, the flow meter can be equipped with a bi-stable flow sensor. Any deviation fron the set point[…]

Buhler SSM

Handling hazardous liquids or gases requires the use of flow meters with the vulnerable parts such as the metering glass protected against breakage. The S-SM safety flow meter provides sealed protection glass around the metering glass and an outer stainless steel shell with a sight window. A variety of construction materials is available to meet[…]

Buhler TGAK3

The Buhler Model TGAK 3 is a complete, portable gas conditioning system in a rugged metal case. The basic model consists of a gas cooler with condensate vessel, a gas pump, filter, moisture detector and a flow meter with needle valve. A version without the pump is also available. The TGAK features a unique fail-safe[…]

Scroll to top