H2S Analyzer – Measure hydrogen sulfide with Applied Analytics
Introducing the OMA H2S analyzer by Applied Analytics, a breakthrough in hydrogen sulfide monitoring. This process gas analyzer measures H2S levels accurately in various industrial environments, ensuring safety and compliance. Its technology detects H2S in multiple settings, from natural gas to wastewater. Discover how the OMA H2S Analyzer can safeguard your operations and comply with safety standards. Contact ASaP for a customized solution to meet your H2S monitoring needs.
Table of contents
ASaP products and services for H2S analyzer
Our comprehensive range of products and services for H2S analyzer include offshore and onsite service, and an extensive selection of gas analysis instruments, sample conditioning, sample probes, and various cabinets and houses for your instruments, tailored to meet the unique requirements of various cryogenic, renewable, and petrochemical applications. We are dedicated to delivering innovative solutions that ensure accurate and efficient operations in the process industry.
Addressing industrial challenges with hydrogen sulfide measurment
Hydrogen sulfide (H2S) poses significant risks in industrial settings, necessitating accurate detection and monitoring. Traditional methods often fall short, lacking in precision and reliability. This gap leads to potential safety hazards and non-compliance with regulatory standards.
Enter the OMA H2S Analyzer by Applied Analytics, supplied by ASaP. This sophisticated hydrogen sulfide analyzer addresses these challenges head-on. Its technology provides real-time, precise H2S measurements in diverse mediums like natural gas, crude oil, and wastewater. Its adaptability ensures comprehensive monitoring, from trace levels to high concentrations, maintaining workplace safety and regulatory adherence.
Advantages of using an OMA hydrogen sulfide analyzer
The OMA H2S Analyzer offers numerous benefits:
- Precision and Speed: Delivers rapid and accurate H2S readings, essential for timely decision-making.
- Versatility: Capable of analyzing various substances, making it suitable for multiple industries.
- User-Friendly: Features an intuitive interface, simplifying the monitoring process.
- Safety Assurance: Designed with safety as a priority, reducing the risk of accidents.
- Cost-Effective: Low maintenance and durable, ensuring long-term savings.
Customer reviews
“We are using OMA H2S Analyzers in our refinery for some time now. Its accurate readings and reliability have significantly improved our standards.”
Analyzer Specialist, Rotterdam Botlek area
OMA H2S analyzer key features
Hydrogen sulfide measurement has evolved significantly. Initially, rudimentary methods provided basic detection, often with substantial limitations. The development of the H2S analyzer marked a significant advancement, introducing precision and reliability into H2S monitoring.
Utilizing ultraviolet-visible (UV-Vis) spectroscopy, it measures H2S concentration with unprecedented accuracy. This method detects H2S’s unique absorbance curve, isolating it from other sample components. The analyzer’s history reflects a commitment to innovation, safety, and efficiency in industrial monitoring.
- Real-time H2S concentration measurement
- Applicable in liquid and gas processes
- High accuracy and dynamic range
- UV-Vis absorbance monitoring
- Suitable for various industrial applications
Applications of the OMA H2S analyzer
The OMA H2S Analyzer’s versatility extends across various industries, including:
- Biogas
- Synthesis gas
- Hydrogen recycle
- CO2 recycle
- Petroleum and natural gas processing
- Wastewater treatment
- Chemical manufacturing
- Environmental monitoring
Technical overview of the OMA H2S analyzer
The OMA H2S Analyzer employs UV-Vis spectroscopy for precise H2S measurement. This technology involves measuring the absorbance of ultraviolet and visible light by the sample. The analyzer’s xenon light source transmits light through the sample in a flow cell, with fiber optic cables carrying the signal.
This process results in a high-resolution absorbance spectrum, allowing for accurate H2S detection. The analyzer’s software, ECLIPSE, processes this data to provide real-time concentration readings. Its design ensures safety, with the sample fluid remaining outside the analyzer enclosure. This technical sophistication positions the OMA H2S Analyzer as a leading solution in gas monitoring.
OMA H2S analyzer models
The OMA H2S Analyzer series includes:
- OMA-300: Wall-mounted, ideal for industrial use.
- OMA-206P: Portable, perfect for field operations.
- OMA-406R: Rackmount, suitable for laboratory environments.
Despite having identical core functions, each model caters to specific use cases with unique form factors and construction materials.
OMA H2S analyzer specifications
General
Measurement Principle | Dispersive ultraviolet-visible (UV-Vis) absorbance spectrophotometry |
Detector | nova II™ UV-Vis diode array spectrophotometer |
Spectral Range | 200-800 nm |
Light Source | Pulsed xenon lamp (average 5 year lifespan) |
Signal Transmission | 600 μm core 1.8 meter fiber optic cables Other lengths available |
Path Length | Application-dependent |
Sample Conditioning | Custom design per application |
Analyzer Calibration | If possible, analyzer is factory calibrated with certified calibration fluids; no re-calibration required after initial calibration; measurement normalized by Auto Zero |
Reading Verification | Simple verification with samples and self-check diagnostic |
Human Machine Interface | Industrial controller with touch-screen LCD display running ECLIPSE™ Software |
Data Storage | Solid State Drive |
OPERATING CONDITIONS | |
Analyzer Environment | Indoor/Outdoor (no shelter required) |
Ambient Temperature | Standard: 0 to 35 °C (32 to 95 °F) Optional: -20 to 55 °C (-4 to 131 °F) To avoid radiational heating, use of a sunshade is recommended for systems installed in direct sunlight. |
Sample Temperature | Standard: -20 to 70 °C (-4 to 158 °F) Optional: up to 150 °C (302 °F) with cooling extensions Contact AAI for temperatures above 150 °C (302°F) |
Sample Pressure | Using standard flow cell: 206 bar (3000 psi) Using immersion probe: 100 bar (1470 psig) |
UTILITIES | |
Electrical | 85 to 264 VAC 47 to 63 Hz |
Power Consumption | 45 watts |
OUTPUTS | |
Standard Outputs | 1x galvanically isolated 4-20mA analog output per measured analyte(up to 3; additional available by upgrade) 2x digital outputs for fault and SCS control |
Optional Outputs | Modbus TCP/IP; RS-232; RS-485; Fieldbus; Profibus; HART; |
Performance
H2S Accuracy in Liquid |
Example ranges below. Custom ranges available. 0-100 mg/L: ±1% full scale or 1 mg/L* *Whichever larger. |
H2S Accuracy in Gas |
Example ranges below. Custom ranges available. Accuracy may be higher at higher pressure. 0-10 ppm (@1 bar): ±1 ppm (Increased pressure will yield increased accuracy); ±0.2 ppm (@5 bar) 0-100 ppm: ±1% full scale or 1 ppm* 0-10,000 ppm: ±1% full scale 0-100%: ±1% full scale *Whichever larger. |
Certifications
Standard Design | General Purpose |
Available Options | ATEX, IECEx, EAC, PESO |
Please inquire with your sales representative for additional certifications (CSA, FM etc.). |
Final thoughts on the applied analytics OMA H2S analyzers
The OMA H2S Analyzer represents a significant advancement in gas monitoring technology. Its precision, versatility, and safety features make it an indispensable process gas analyzer in various industrial applications. By choosing this analyzer, industries not only ensure compliance with safety standards but also embrace a solution that boosts operational efficiency. The OMA H2S Analyzer, supplied by ASaP, is more than just a device; it’s a commitment to safety, reliability, and technological advancement.
Get in Touch with ASaP
For detailed information and to discuss how the OMA H2S Analyzer can benefit your operations, contact our specialists at ASaP. Reach out to us, and we will explore the possibilities together.
FAQ: Answering questions about H2S analyzers
An H2S Analyzer is a device for measuring hydrogen sulfide concentration in various environments and industries.
It accurately measures H2S levels, ensuring safety and compliance with environmental standards.
Used in gas processing, wastewater treatment, environmental monitoring, and more.
Real-time measurement, UV-Vis spectroscopy, adaptable for liquid/gas processes, and safety-focused design.
Contact Our H2S analyzer specialist today
For personalized assistance and further H2S analyzer inquiries, please contact our specialist at ASaP. We are here to help and provide the support you need.
Contact our H2S analyzer specialist directly
You can contact us is you have a question about H2S analyzer when it suits you. See our specialist’s contact information below.
🔧
📨
📞
🔗
Let our H2S analyzer specialist contact you
Let us know how we can reach you to discuss H2S analyzer. We will only use this information for contacting you.