The Ametek WDG 1200 and 1210 Insitu flue gas analyzers are rugged, reliable flue gas oxygen analyzers for net oxygen that use industry-proven zirconium oxide sensor technology. The outer probe tube is 310 stainless steel so no abrasion shield is needed for most applications. The controller features precision temperature control for optimum stability, built-in diagnostics, and over-temperature protection. Modbus interface and 4-20 mA outputs are standard. The unique sensor design allows the entire sensor assembly, including the heater, to be removed without disturbing the outer protection tube which remains in the process. This makes field service fast and easy, and because there is no need to return the probe to the factory for repair, there’s no expensive downtime.
Insitu Probe | |
Accuracy (O2) | ±1% of measured value or ±0.05% oxygen, whichever is greater |
Response | Cal Gas <3 seconds; process <20 seconds (63% of step change) |
Drift | <0.1% of cell output per month (less than 0.005% O2, per moth with 2% O2 applied) |
Linearity | ±1% of output span |
Repeatability | ±1% of output span |
Max. Flue Gas Temp | 1472ºF (800ºC) |
Environment | Indoor/Outdoor Use Ambient Temp: -5ºF to 160ºF (-20ºC to 71ºC) Relative Humidity: 10% to 95%, non-condensing |
Probe Lengths | 9″ (0.23 m), 18″ (0.45m), 36″ (0.9m), 72″ (1.8 m), 108″ (2.7m) |
Enclosures | NEMA 4X/IP65 |
the Future of Ametek WDG 1200 and 1210 Insitu for Industrial Process Analytics: The OMA Process Analyzer
At Analytical Solutions and Products, we are constantly seeking to innovate and provide our clients with the most advanced solutions in Ametek WDG 1200 and 1210 Insitu for industrial process analytics. This is why we have chosen the OMA Process Analyzer by Applied Analytics as the new standard, replacing this Ametek process gas analyzer. We firmly believe that the OMA Process Analyzer represents the future of industrial process analytics. Its advanced technology and robust design align perfectly with our commitment to innovation and excellence in the field. By integrating the OMA Process Analyzer into your operations, you are not just upgrading your equipment; you are stepping into the future of industrial analysis.
Why the OMA Process Analyzer instead of Ametek WDG 1200 and 1210 Insitu?
The OMA Process Analyzer stands out due to its remarkable capability to continuously measure the components of a liquid or gas process stream with utmost precision. This feature makes it an invaluable tool in a wide range of industrial applications, ensuring efficiency and accuracy in real-time analysis.
Maintaining our commitment to Ametek service
Transitioning to new technology does not mean a compromise on service for Ametek WDG 1200 and 1210 Insitu. We are dedicated to maintaining the highest standard of service on your installed base. Our team of experts is equipped to ensure a smooth transition and continuous support, keeping your operations running seamlessly. We understand that every industrial application has its unique requirements. Therefore, we invite you to contact our analyzer specialist for a detailed discussion on how the OMA Process Analyzer can be integrated into your specific processes. Our specialist will provide you with tailored information, addressing your particular needs and concerns.
Ametek WDG 1200 and 1210 Insitu flue gas analyzers PDF
Ametek WDG 1200 and 1210 HPII Explosion proof Division 1
Explosion proof Division 1, convective analyzers for direct measurement of oxygen in flue gas streams up to 1537°C. The Ametek WDG 1200 and 1210 Insitu flue gas analyzers HPII XP analyzers mount directly on the combustion process and are designed for direct measurement in flue gas applications without the need for installing a high temperature bypass system, a requirement on most petrochemical insitu analyzer applications. The elimination of the high temperature bypass system with the direct convection measurement of the Ametek WDG 1200 and 1210 Insitu flue gas analyzers HP XP analyzer insures a faster analyzer response to process changes and reduced installation cost by direct process flange mounting and no need for instrument air for sample transport or purge. These analyzers are suitable for gas streams up to 1537°C and for corrosive gas streams with sample wetted parts in Hastelloy® or Inconel®. The analyzers can be provided with integral on-board electronics or a remote mount control unit installed up to 300m from the sensor (Ametek WDG 1200 and 1210 Insitu flue gas analyzers HPII XP). Analog current output and MODBUS communication are provided for process measurement and communication.
Ametek WDG 1200 and 1210 Insitu flue gas analyzers HPII XP PDF
Is the OMA process analyzer suitable for your process?
Contact Our Ametek WDG 1200 and 1210 Insitu specialist today
For personalized assistance and further Ametek WDG 1200 and 1210 Insitu inquiries, please contact our specialist at ASaP. We are here to help and provide the support you need.
Contact our Ametek WDG 1200 and 1210 Insitu specialist directly
You can contact us is you have a question about Ametek WDG 1200 and 1210 Insitu when it suits you. See our specialist’s contact information below.
🔧
📨
📞
🔗
Let our Ametek WDG 1200 and 1210 Insitu specialist contact you
Let us know how we can reach you to discuss Ametek WDG 1200 and 1210 Insitu. We will only use this information for contacting you.